      <title>Industrial PC RS-232 Garbled Data: Software Correct, Hardware Fine — Ground Loop Postmortem</title>
      <link>https://intent.me/en-us/blog/tech/rs232-ground-loop-postmortem/</link>
      <pubDate>Wed, 02 Sep 2026 12:00:00 +0800</pubDate>
      <guid>https://intent.me/en-us/blog/tech/rs232-ground-loop-postmortem/</guid>
      <description>An industrial PC (TI AM64x heterogeneous SoC, A53 Linux + R5F RTOS, 24V supply) garbles continuously on a 3-wire RS-232 port at correct 115200 8N1 settings. Via SSH, the tx/rx/fe counters in /proc/tty/driver/serial verified both directions of the channel, ruling out software and unit defects; garbling persisted with only GND connected and vanished the moment the laptop&amp;rsquo;s power adapter was unplugged — a ground loop between the 24V industrial supply and mains. Dual-isolation converter verified in practice: no interference with the laptop plugged in.</description>